API RP‐2SIM (API 2014b) states that flooded member detection (FMD) can provide an acceptable alternative to close visual inspection of preselected areas in a level III survey. Engineering judgment should be used to determine the optimum use of FMD and close visual inspection of joints. Close visual inspection of pre‐selected locations for corrosion monitoring should be included as part of the level III survey.
Inspection tools and techniques are covered in general terms in API RP‐2SIM (API 2014b), including details of the standard methods as covered in Chapter 4 of this book. Evaluation of damaged components and repair is addressed in the recommended practice in line with Chapters 7and 8 of this book. The standard also addresses the structural assessment process, outlining a series of approaches. Four different levels of assessment are developed, which include:
simple methods, e.g. comparison with a similar platform;
design methods, e.g. linear (elastic) methods to check the platform member‐by member, similar to the approach used for the design of new platforms;
ultimate strength method, e.g. using a non‐linear or equivalent linear method to determine platform performance on a global basis;
alternative methods, e.g. using historical performance of the platform or explicit probabilities of survival of the platform for the assessment.
Personnel qualifications are listed for personnel responsible for conducting the evaluation and developing the inspection strategy, as further discussed in Section 4.4.5.
2.3.3 API RP‐2FSIM (Floating Systems Integrity Management)
API RP‐2FSIM (API 2019a) is a Recommended Practice (RP) intended to be used by owners and engineers in the development, implementation and delivery of a process to maintain system integrity of floating production systems (FPSs), which includes tension leg platforms (TLPs). The specifications, procedures and guidance provided within the RP are based on internationally recognized industry standards and on global industry best practices. This RP does not cover moorings, which are separately covered by API RP‐2MIM (API 2019b).
API RP‐2FSIM (API 2019a) states that an inspection plan should define the scope and frequency of inspection, the tools and techniques to be used and the deployment methods. This plan should be developed for the FPS structural and system components. The main objectives of the inspection plan are to identify areas of corrosion, coating deterioration, damage due to overloading, impact or abrasion, as well as areas affected by marine growth and debris. The plan should also measure or confirm the CP potentials, sensors and alarms, marine system functions and mooring equipment functions. The inspection plan should consist of a set of scheduled work scopes to be performed over the service life of the FPS. In addition, unscheduled surveys should follow an unexpected event such as exposure to a near‐level design event (e.g. hurricane).
API RP‐2FSIM (API 2019a) states that underwater surveys should be performed on the submerged areas of the hull and this should include external marine system components and the mooring system hull attachments. These surveys should also confirm that the corrosion protection system of the external hull is functioning adequately. It is recommended that external hull surveys can be performed on a continuous cycle where a specified percentage of the hull is inspected over a period and at the end of the period all of the hull is covered. A default inspection program for the hull structure is included with calendar‐based intervals and the extent of structure to be inspected by different inspection methods (GVI, CVI, ultrasonic testing and weld inspection).
Monitoring of the structure and marine systems are recommended in API RP‐2FSIM (API 2019a) in addition to inspection. Typical monitoring methods for floating structures are further discussed in Chapter 5.
API RP‐2FSIM (API 2019a) describes an assessment process and acceptance criteria, similar to other relevant API RPs, including the assessment of fatigue damage. The fatigue assessment should assess the fatigue loading behaviour and analyse the remaining fatigue life of critical locations such as welded joints and details in highly stressed areas. If the predicted fatigue life exceeds allowable levels, API RP‐2FSIM (API 2019a) states that improvement options may be considered, including local structural modifications, increased inspection frequency, change of loading conditions and using improved inspection techniques.
Methods for the repair of damage and modifications are described in API RP‐2FSIM (API 2019a), including completely renewing a locally damaged area by means of a structural repair. This may involve the addition of a new structure (e.g. stiffening to reinstate the capacity in a damaged area). Modification of the structural details may be used to minimise the potential for future damage, particularly fatigue (e.g. by grinding).
2.3.4 ISO 19902
The development of the international standard ISO 19902 (ISO 2007), concerned with fixed offshore structures began in 1993, including a section on structural integrity management in the early drafts. This standard was first issued formally in 2007, but the early drafts were used as the basis for structural integrity management in the period from 1993 to 2007. In 2019 the SIM part of this standard was transferred to a new ISO standard, ISO 19901‐9 (ISO 2019a), which focused on structural integrity management and assessment of existing structures.
The ISO 19902 (ISO 2007) took into account all the issues and methods that had been used to inspect, monitor, evaluate and assess fixed offshore steel structures over the previous years. ISO 19902 (ISO 2007) described four different types of inspection of the structure as shown below:
baseline: inspection soon after installation and commissioning to detect any defects arising from fabrication or damage during installation;
periodic: inspection to detect deterioration or damage over time and discover any unknown defects;
special: inspection required after repairs or to monitor known defects, damage or scour;
unscheduled: inspection undertaken after a major environmental event such as a severe storm, hurricane, earthquake or after an accidental event such as a vessel impact or dropped objects.
ISO 19902 (ISO 2007) stated that “the purpose of in‐service structural inspection is to determine, with a reasonable level of confidence, the existence and extent of deterioration, defects, or damage. Data collected during an inspection are needed to verify the integrity of the structure”.
ISO 19902 (ISO 2007) described the process of managing the integrity of structures with four major elements as shown in Figure 9, where inspection is the key element of both the long‐term surveillance plan and particularly the surveillance execution. The remaining two processes include the storage of inspection data and the evaluation of possible anomalies found during inspection.
Figure 9 Structural integrity management cycle (surveillance includes inspection of the condition, determination of loading, review of documents, etc., needed to determine changes that may affect the safety of the structure).
Source: Based on ISO (2007), ISO 19902:2007 Petroleum and natural gas industries—Fixed steel offshore structures,